| 6 x 1 MESFET Array Prototype with patch antennas
4GHz optimum efficiency oscillator design (43% DC-to-RF
conversion)
Results:
 |
Continuous scanning from -40 degrees to +40 degrees off
broadside |
 |
accomplished by adjusting end-element frequencies (drain
bias) |
Excellent correlation with theory
|